Heat Pump Size Calculator (Heating Load in BTU)

Enter the floor area, climate zone and insulation. Get the heating load and a heat pump size in tons.

Free, no sign-upInstant resultsUpdated October 2026
ft²
Heating load
–
How we calculated this

    For estimating and educational purposes only. Results are approximate and are not a substitute for a licensed professional, the manufacturer's instructions or your local code. Disclaimer

    Embed this calculator on your site

    Free for any website or blog. Copy the code below and paste it into an HTML block. Keep the credit link.

    Heating BTU per square foot

    The heat a house loses on the coldest days depends on the climate and how well it is built. As a rule of thumb, this calculator uses these values for average insulation, then −20% for a well-insulated home or +25% for an old, drafty one:

    IECC climate zoneBTU/h per ft²
    Zones 1–2 (hot)15
    Zone 3 (warm)25
    Zone 4 (mixed)32
    Zones 5–7 (cold)40

    Worked example

    A 1,800 ft² house in zone 4 with average insulation: 1,800 × 32 = 57,600 BTU/h (16.9 kW), or 4.8 tons, so a 5-ton heat pump. In cold zones the heat pump must deliver that output at the design temperature, so compare against the capacity at 5 °F, not the nominal rating.

    Heat pump vs furnace sizing

    Heat pumps are sold by cooling tons; their heating output drops as it gets colder. Furnaces are sold by input BTU: a 95% AFUE furnace with 60,000 BTU input delivers about 57,000 BTU/h. For permits and rebates, a Manual J calculation is the standard.

    Frequently asked questions

    What size heat pump do I need for 2,000 sq ft?

    In zone 4 with average insulation about 64,000 BTU/h (5.3 tons); a well-insulated home about 51,000 BTU/h. Always check the output at your design temperature.

    How many BTU per square foot to heat a house?

    Roughly 15 BTU/ft² in hot climates to 40 BTU/ft² in cold ones for an average home; well-insulated homes need less.