How to size a solar system
Divide your daily energy use by the number of peak sun hours at your location, then adjust for real-world losses from wiring, inverter, heat and dirt. The result is the DC system size in kilowatts. Divide by the panel wattage to get the panel count.
Example
900 kWh/month is 29.6 kWh/day. With 4.5 sun hours and 14% losses: 29.6 ÷ (4.5 × 0.86) = 7.64 kW. With 400 W panels that is 19.1, so 20 panels (8.0 kW).
Peak sun hours by region
| Region | Typical peak sun hours |
|---|---|
| Arizona, Nevada, Southern California | 6.0–7.0 |
| Texas, Florida, Southeast | 4.8–5.5 |
| Colorado, Utah, Mountain West | 5.0–6.0 |
| Midwest | 4.0–4.7 |
| Northeast, Great Lakes | 3.5–4.2 |
| Pacific Northwest | 3.0–4.0 |
A peak sun hour is one hour of sunlight at 1,000 W per square meter. It is an annual average; winter is lower and summer higher.
How many 400 W solar panels do I need? (by kWh and sun hours)
Number of 400 W panels needed to cover 100% of a monthly electricity use from 200 to 2,000 kWh, for 3 to 6 peak sun hours per day.
Show full table
| Monthly use | 3.0 h | 3.5 h | 4.0 h | 4.5 h | 5.0 h | 5.5 h | 6.0 h |
|---|---|---|---|---|---|---|---|
| 200 kWh | 7 | 6 | 5 | 5 | 4 | 4 | 4 |
| 300 kWh | 10 | 9 | 8 | 7 | 6 | 6 | 5 |
| 400 kWh | 13 | 11 | 10 | 9 | 8 | 7 | 7 |
| 500 kWh | 16 | 14 | 12 | 11 | 10 | 9 | 8 |
| 600 kWh | 20 | 17 | 15 | 13 | 12 | 11 | 10 |
| 700 kWh | 23 | 20 | 17 | 15 | 14 | 13 | 12 |
| 800 kWh | 26 | 22 | 20 | 17 | 16 | 14 | 13 |
| 900 kWh | 29 | 25 | 22 | 20 | 18 | 16 | 15 |
| 1,000 kWh | 32 | 28 | 24 | 22 | 20 | 18 | 16 |
| 1,100 kWh | 36 | 31 | 27 | 24 | 22 | 20 | 18 |
| 1,200 kWh | 39 | 33 | 29 | 26 | 23 | 21 | 20 |
| 1,300 kWh | 42 | 36 | 32 | 28 | 25 | 23 | 21 |
| 1,400 kWh | 45 | 39 | 34 | 30 | 27 | 25 | 23 |
| 1,500 kWh | 48 | 41 | 36 | 32 | 29 | 27 | 24 |
| 1,600 kWh | 51 | 44 | 39 | 34 | 31 | 28 | 26 |
| 1,700 kWh | 55 | 47 | 41 | 37 | 33 | 30 | 28 |
| 1,800 kWh | 58 | 50 | 44 | 39 | 35 | 32 | 29 |
| 1,900 kWh | 61 | 52 | 46 | 41 | 37 | 34 | 31 |
| 2,000 kWh | 64 | 55 | 48 | 43 | 39 | 35 | 32 |
Same assumptions as the calculator: daily kWh = monthly ÷ 30.42, system kW = daily ÷ (sun hours × 0.86) for 14% system losses (NREL PVWatts default), panels rounded up. Peak sun hours: Southwest 6–7, Southeast 5, Midwest 4–4.5, Northeast and Pacific Northwest 3.5–4.
Solar system size in kW by monthly kWh and sun hours
DC system size (kW) needed for the same monthly use and sun hours, before rounding up to whole panels.
Show full table
| Monthly use | 3.0 h | 3.5 h | 4.0 h | 4.5 h | 5.0 h | 5.5 h | 6.0 h |
|---|---|---|---|---|---|---|---|
| 200 kWh | 2.55 kW | 2.18 kW | 1.91 kW | 1.70 kW | 1.53 kW | 1.39 kW | 1.27 kW |
| 300 kWh | 3.82 kW | 3.28 kW | 2.87 kW | 2.55 kW | 2.29 kW | 2.08 kW | 1.91 kW |
| 400 kWh | 5.10 kW | 4.37 kW | 3.82 kW | 3.40 kW | 3.06 kW | 2.78 kW | 2.55 kW |
| 500 kWh | 6.37 kW | 5.46 kW | 4.78 kW | 4.25 kW | 3.82 kW | 3.47 kW | 3.19 kW |
| 600 kWh | 7.64 kW | 6.55 kW | 5.73 kW | 5.10 kW | 4.59 kW | 4.17 kW | 3.82 kW |
| 700 kWh | 8.92 kW | 7.64 kW | 6.69 kW | 5.95 kW | 5.35 kW | 4.86 kW | 4.46 kW |
| 800 kWh | 10.19 kW | 8.74 kW | 7.64 kW | 6.80 kW | 6.12 kW | 5.56 kW | 5.10 kW |
| 900 kWh | 11.47 kW | 9.83 kW | 8.60 kW | 7.64 kW | 6.88 kW | 6.25 kW | 5.73 kW |
| 1,000 kWh | 12.74 kW | 10.92 kW | 9.56 kW | 8.49 kW | 7.64 kW | 6.95 kW | 6.37 kW |
| 1,100 kWh | 14.02 kW | 12.01 kW | 10.51 kW | 9.34 kW | 8.41 kW | 7.64 kW | 7.01 kW |
| 1,200 kWh | 15.29 kW | 13.11 kW | 11.47 kW | 10.19 kW | 9.17 kW | 8.34 kW | 7.64 kW |
| 1,300 kWh | 16.56 kW | 14.20 kW | 12.42 kW | 11.04 kW | 9.94 kW | 9.03 kW | 8.28 kW |
| 1,400 kWh | 17.84 kW | 15.29 kW | 13.38 kW | 11.89 kW | 10.70 kW | 9.73 kW | 8.92 kW |
| 1,500 kWh | 19.11 kW | 16.38 kW | 14.33 kW | 12.74 kW | 11.47 kW | 10.42 kW | 9.56 kW |
| 1,600 kWh | 20.39 kW | 17.47 kW | 15.29 kW | 13.59 kW | 12.23 kW | 11.12 kW | 10.19 kW |
| 1,700 kWh | 21.66 kW | 18.57 kW | 16.25 kW | 14.44 kW | 13.00 kW | 11.81 kW | 10.83 kW |
| 1,800 kWh | 22.93 kW | 19.66 kW | 17.20 kW | 15.29 kW | 13.76 kW | 12.51 kW | 11.47 kW |
| 1,900 kWh | 24.21 kW | 20.75 kW | 18.16 kW | 16.14 kW | 14.53 kW | 13.20 kW | 12.10 kW |
| 2,000 kWh | 25.48 kW | 21.84 kW | 19.11 kW | 16.99 kW | 15.29 kW | 13.90 kW | 12.74 kW |
Same assumptions as the calculator: daily kWh = monthly ÷ 30.42, system kW = daily ÷ (sun hours × 0.86) for 14% system losses (NREL PVWatts default), panels rounded up. Peak sun hours: Southwest 6–7, Southeast 5, Midwest 4–4.5, Northeast and Pacific Northwest 3.5–4.
Frequently asked questions
How many solar panels do I need for 1,000 kWh a month?
With 4.5 sun hours and 400 W panels, about 22 panels (an 8.5 kW system). In sunnier states like Arizona, about 15 panels.
How much roof space do solar panels need?
A 400 W residential panel is about 21 square feet. A 20-panel system needs roughly 420 sq ft of usable, unshaded roof.
What are system losses?
Energy lost to inverter conversion, wiring, heat, soiling, shading and panel mismatch. NREL's PVWatts uses 14% as a default.