A typical 600VA UPS is rated about 360 W and uses 1 × 12 V 7 Ah battery. At half load (180 W) it runs about 12m. Lighter loads last much longer: about 14m with an office PC and monitor (150 W) and 2h 43m with just a router and modem (20 W).
Free, no sign-upInstant resultsUpdated October 2026
Runtime
–
How we calculated this
Was this calculator helpful?Thanks for the feedback!
For estimating and educational purposes only. Results are approximate and are not a substitute for a licensed professional, the manufacturer's instructions or your local code. Disclaimer
Estimates for new batteries at 25 °C and 90% inverter efficiency, using Peukert's law (k = 1.2). Battery packs vary by brand: check yours and enter it in the calculator. Batteries older than 3 years can deliver half of this.
About 14m for an office PC with a monitor (150 W) and 6m for a desktop with two monitors (300 W).
Why does half the load give more than double the runtime?
Lead-acid batteries deliver less of their rated capacity at high current (Peukert effect). At light loads you get close to the full Wh; at heavy loads much less.
How much load can a 600VA UPS take?
Its rating is about 360 W. Keep the load under 80% (288 W) so the inverter and batteries are not stressed.